When one button of a transmitter (RF, UR, or BR) is activated, all
zones assigned to other buttons on that transmitter are cleared. This
also applies to 5816 and 5817 transmitters which have multiple loops
(zones).
Any transmitter that is not “enrolled” will not turn off its zone
number.
Exit this mode by keying Installer code + OFF.
b. GO/NO GO TEST MODE: By pressing Installer code + # + 4 on
keypad, a mode similar to the user test mode (code + TEST) is entered,
but the wireless receiver gain is reduced. Checking in this mode assists
in determining good mounting locations for the transmitters when the
system is being installed and verifies that the RF transmission has
sufficient signal amplitude margin for the installed system.
Exit the mode by entering Installer code + OFF.
NOTE: System Test Mode (code + test) will be automatically terminated
in approximately 4 hours if the installer or user does not manually
terminate it.
This insures that Fire and Panic zones will not remain disabled.
However, Sniffer Mode (installer code + # + 3) does not automatically
expire. You must manually exit (installer code + OFF) sniffer mode to
return to normal operation. Sniffer Mode also terminates if a user arms the
system.
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the installer and frequent testing by
the user are vital to continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing and offering a regular maintenance
program to the user as well as acquainting the user with the proper operation and limitations of
the alarm system and its component parts. Recommendations must be included for a specific
program of frequent testing (at least weekly) to insure the system's proper operation at all times.