Section 14. MECHANICS OF PROGRAMMING
This section provides information on how to use the system's programming
modes. It will enable you to understand how to enter and exit programming
mode, and how to program the data fields and how to use the user-friendly
interactive modes (
56,
80,
81,
82,
83).
If RF zones or wired expansion will be used, the following program fields must
be programmed (as required) before doing any zone programming.
22 RF SYSTEM
25 WIRED ZONE EXPANSION
In addition, the following fields must be programmed before completing the installation.
20 INSTALLER CODE
General Programming Information
Characteristics for each installation are stored in non-removable, electrically
erasable, non-volatile EEPROM memory. These must be programmed for the
particular installation to establish its specific alarm and reporting features.
It is possible to program the system at any time, even at the installer's
premises prior to the actual installation. Simply apply power temporarily to
the control and then program the unit as desired.
IMPORTANT:
You cannot enter the programming mode unless the
security system is disarmed.
There are two programming modes: data field programming and interactive
(menu) mode programming. Data field programming is used for setting
various system options and interactive programming is used for
programming zone information, programming relay outputs, and for enrolling
transmitter serial numbers.
To program the system, you must use a AM6139 2-line Alpha keypad
connected to the keypad terminals on the control (4, 5, 6, & 7). Also, the
security system must be disarmed. The Alpha keypad need not necessarily
remain in the system after programming.
Programming can also be performed remotely from the installer’s office/home,
using an IBM personal computer, a modem, and V-Link downloading
software. See the REMOTE PROGRAMMING AND CONTROL
(DOWNLOADING) section.
Entering Program Mode
You may use one of the following methods:
a) Press both the [
] and [#] keys at the same time within 50 seconds after
power is applied to the Control, or
b) After power up, enter the Installer code (4 1 1 2) + 8 0 0.
This method is disabled if you exit the program mode using
98 instead of
99. See “Exiting Program Mode” paragraph later in this section.
If a different Installer code is subsequently programmed, use it instead of
4112 to gain access to the Programming mode.
Following entry into program mode, data field
20 will be displayed (this is
the first data field in the system). The system will now accept entries for
field
20.
Programming a Data Field
1. Press [
] plus Field No. (for example,
21), then make the required entry.
2. When you have completely programmed a data field, the keypad will
“beep” three times and then automatically display the next data field in
sequence. To go to a different field, press [
] plus the desired field No.