Datacom Systems D56 Průvodce řešením problémů Strana 48

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 104
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 47
–4
8
3. If the number of digits that you need to enter in a data field is less than
the maximum digits available (for example, the phone number field), enter
the desired data, then press [
]
and the next data field number to be
programmed.
4. If you try to enter a non-existent field, the keypad will display EE or
Entry Error. Simply re-enter [
] plus a valid field number.
Reviewing a Data Field/Erasing an Entry in a Data Field
Press [#] plus Field No. Data will be displayed for that field number. No
changes will be accepted in this mode.
To delete an entry in a field, press [
] plus Field No. + [
]. (Applies only to
fields
40–
44,
88, and
94).
Interactive Mode Programming (
56,
80,
81,
82 and
83)
Typical prompt
displayed during
interactive mode
programming
Enter Zn Num.
(00 = Quit) 01
Zone Number
Press [
] plus interactive mode no. (for example,
56). The Alpha keypad
will display the first of a series of prompts requesting entries.
A detailed procedure (with displays of prompts) is provided in later sections
of this manual.
Interactive Mode Used To Program
56 Zone Programming Zone characteristics, report codes, alpha
descriptors and serial numbers
80 Relay Programming 4229 or 4204 Relay modules, or Powerline
Carrier devices
81 Zone List Programming Zone Lists for relay/powerline carrier
activation
82 Alpha Programming Zone alpha descriptors
83 Sequential Mode 5800 series transmitter serial numbers
Loading Factory Defaults
To load the factory defaults, enter the programming mode, press
97, then
exit the programming mode.
Do not press
97 to load defaults if any programming has been done
previously—data already programmed into the system will be changed!
96 resets all the Subscriber Account numbers and CSID in preparation for
an initial download.
Programming System Setup Fields
The following program fields must be programmed before doing any zone
programming.
22 RF SYSTEM 0
Enter 1 if 5881/5882 RF receiver is being used; enter 0 if no receiver is
being used. Default is 0 (none).
25 WIRED ZONE EXPANSION 0
Use this field to select the type of expansion unit being used, as follows:
0 = none; 1 = 4219; 2 = 4229; 3 = 4204. Default is 0.
Exiting the Programming Mode
99 allows re-entry into the program mode using Installer Code + 8 0 0.
98 inhibits re-entry into the programming mode using the Installer code.
Zobrazit stránku 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 103 104

Komentáře k této Příručce

Žádné komentáře