SUMMARY OF ARMING MODES
Features for Each Arming Mode
Arming
Mode
Exit
Delay
Entry
Delay
Perimeter
Armed
Interior
Armed
AWAY Yes Yes Yes Yes
HOME Yes Yes Yes No
INSTANT Yes No Yes No
*MAXIMUM Yes No Yes Yes
Panic Keys
*This feature is not advertised in order to prevent false alarms by the user
while at home with ALL protected zones (interior and exterior) armed.
There are three panic key pairs that can be used to manually initiate alarms
and send a report to the central station.
Each can be individually programmed for 24-hour Silent, Audible, Personal or
Fire Emergency responses. The panic function is activated when both keys of
the appropriate key pair are pressed at the same time.
The panic functions are identified by the system as follows:
Keys Displayed as Zone
[1] & [
]95
[
] & [#] 99
[3] & [#] 96
Important: For the Silent Panic functions to be of practical value, the
system must be connected to a central station.
Relay/Powerline Carrier
Devices
(if used)
If relay outputs (via a 4204, or 4229), or Powerline Carrier devices are used,
two keypad entries available to the user are included. They can manually
activate or deactivate the device(s) for starting or stopping some action, such
as turning lights on or off, etc.
These keypad entries are:
Security Code + [#] + [7] + Device # activates (starts) that device.
Security Code + [#] + [8] + Device # de-activates (stops) that device.
4285/4286 Phone Module
(if used)
Refer to the separate instructions supplied with the Phone Module for
information concerning its operating procedures.
Note: The Phone Module cannot be used to add user codes in this system.
User codes must be added by using a wired keypad.
Exit Error Alarm
Displays
(if programmed)
A display of "CANCEL ALARM" or "CA" and a zone indication will
appear if an exit or interior zone contained a fault during closing at the
time the exit delay ended (e.g., exit door left open), but the system was
disarmed during the entry delay time. The alarm sounder and keypad
sound continuously, but stop when the system is disarmed. No message
will be transmitted to the central station.
A display of "EXIT ALARM" or "EA" and a zone indication will
appear if an exit or interior zone contained a fault during closing at the
time the exit delay ended, but the system was NOT disarmed during
the entry delay time. The alarm sounder and keypad sound
continuously until the system is disarmed (or timeout occurs). An "exit
alarm" message is sent to the central station.
The "EXIT ALARM" display, etc. will also result if an alarm from an
exit or interior zone occurs within two minutes after the end of an exit
delay.
In any of the above cases, use a second OFF sequence (code plus OFF key) to
clear the display.