5800 Series Transmitters Table
Also refer to APPENDIX A near end of this manual for transmitter input loops/button locations.
Model Description Input Type And Special Notes
5801 Wireless Panic Unit has 4 pushbuttons, each with a unique Input (loop) code.
Transmitter Each pushbutton must be assigned to a zone.
Enroll as “3” for RF (supervised), or “4” for UR (unsupervised).
Note: Input loop (button) No. 4 must always be used.
5802 Pendant Belt Clip Enroll as “5” for BR (single pushbutton type transmitter).
5802CP (Personal Emergency)
Transmitters
5802MN Miniature Personal Enroll as “3” for RF (supervised), or “4” for UR (unsupervised).
Emergency Trans. Single pushbutton type transmitter.
5804 Wireless Key Has 4 pushbuttons, each with a unique input (loop) code.
Transmitter Each pushbutton must be assigned to a zone.
Enroll as “5” for BR (button type transmitter).
Note: All buttons must be assigned the same Input Type.
5806 Wireless Enroll as “3” for RF (supervised).
5807 Photoelectric At the “INPUT S/N” prompt, fault the detector as follows:
5808 a) On many detectors, press the special test switch (not test button)
provided for faulting the detector (see detector’s instructions) then
release.
Note: With some detectors, two contacts must be shorted to fault the
detector. Disengage detector’s cover and swing cover open – these
contacts are on the PC board near a blue jumper (see detector’s
instructions). Momentarily short these contacts with a small
screwdriver.
Two keypad beeps will occur when the detector is faulted the first
time.
b) Wait 6–8 seconds, then press and release the test switch (or
momentarily short the contacts) again. 3 beeps will occur if the control
has accepted the input code, and a summary display showing the
enrolled input (loop) No. will appear.
5816 Door/Window Has two unique input (loop) zones: one for a wired closed circuit contact loop,
Transmitter and the other for a built-in reed switch (used in conjunction with a magnet).
Either or both may be used.
Enroll as “3” for RF (supervised).
5817 Multi-Point Universal Has three unique input (loop) codes: one for a DIP switch set "Primary"
Transmitter contact loop, and the others for two "Auxiliary" closed circuit contact loops.
The "Primary" loop may be set for:
a) Repeating or Single Transmission,
b) Normally Open or Normally Closed Circuit
c) Slow or Fast Response
d) 3-Minute or No Transmission Inhibit.
DIP Switches: Set all DIP switches to the OFF position when enrolling the
serial number.
Enroll as “3” for RF (supervised).
Note: All loops must be assigned the same Input Type.
5818 Recessed Magnetic Enroll as “3” for RF (supervised).
Contact Transmitter
5819 Shock Processor Has three unique input (loop) zones: one for a wired closed circuit contact loop,
Transmitter one for use with inertia type shock detectors (mounted externally), and one for
a built-in reed switch (used in conjunction with a magnet).
Enroll as “3” for RF (supervised).
5849 Glassbreak Enroll as “3” for RF (supervised).
Detector/Transmitter
5890 PIR Detector/ Enroll as “3” for RF (supervised).
Transmitter The cover must be on the unit when enrolling the serial number.
When “enrolling” a transmitter’s ID code(s), any PIR that may be in the vicinity (and is not being enrolled) should be
covered with a cloth, tissue, etc., to prevent activation of that PIR.