–58–
✱
68 CANCEL REPORT CODE (See box on page 56). 1 | 0
This is sent upon disarming of the system after an alarm condition
was reported.
RESTORE
REPORT CODES
(
✱
70 –
✱
76)
✱70 ALARM RESTORE REPORT CODE, 1st DIGIT 1
This is sent when the zone that caused an alarm is restored to its
non-faulted condition. 2nd digit is automatically sent as the 2nd digit
of the zone alarm report code programmed in field ✱56, if expanded
or 4+2 reporting is selected.
✱
71 TROUBLE RESTORE REPORT CODE 1 | 0
See box. This is sent when a trouble in a zone is restored.
✱
72 BYPASS RESTORE REPORT CODE 0 | 0
See box on page 56. This is sent when a zone that has been bypassed
is un-bypassed.
✱
73 AC RESTORE REPORT CODE 0 | 0
This is sent when AC power has been restored after an AC power
outage. See box on page 56. Reports with Subscriber No.
✱
74 LOW BAT RESTORE REPORT CODE 1 | 0
This is sent when a system low battery condition is restored to
normal. See box on page 56). Reports with Subscriber No.
✱
75 RF XMTR LOW BATTERY RESTORE CODE 1 | 0
See box on page 56. This is sent when a transmitter that previously
sent in a low battery message has sent a message indicating it no
longer has a low battery condition.
✱
76 TEST RESTORE REPORT CODE 0 | 0
This is sent when the test mode is exited. See box on page 56.
Reports with Subscriber No. A restore code entered here will cause a
restore message to be sent when Test mode is exited.
✱
88 PAGER CHARACTERS
|||||||||
|||||
Up to 16 digits may be entered in this field to signal a pager. Those
16 digits may be composed of a pin #, pauses, subscriber IDs, or any
special digits that the end user specifies. All 16 digits do not have to
be used. The preceding 16 digits (if any) will be followed by seven (7)
more digits defined as follows:
• a three (3) digit event code:
911 = Alarm
811 = Trouble
101 = Opening (disarm)
102 = Closing (arm AWAY)
• a four (4) digit user/zone number:
The first two digits will always be 00 followed by the two digit
user or zone #. Paging is enabled in the Split/Dual reporting
field
✱
49 by entering a number greater than 5.
NOTE: Some pagers may require an additional delay (pause) to be
programmed into this field in order to receive the entire
message. An entry of [#] + 13 = 2-second pause.
✱
89 EVENT LOG 80% FULL REPORT CODE 0 | 0
If an Event Logging selection is made in field
✱
90, a message can be
sent to the central station receiver when the log is 80% full. If the log
becomes full, a new message will overwrite the oldest message in the
log.
Note: Aside from the selection made by the installer in field
✱
90, all
control and readout from the log is accomplished via the Downloader.