33 ALARM BELL TIMEOUT 1
0 = No timeout
1 = 4 min
2 = 8 min
3 = 12 min
4 = 16 min
This field determines whether the external sounder will shut off after
time allotted, or continue until manually turned off.
UL installations: must be set for a minimum of 4 min (option 1)
NOTE: If the fire sounder of
✱
32 is programmed for no timeout with
✱
33 programmed for 4 to 16 minutes of alarm bell ringing, and a
burglary alarm is triggered at the same time a fire is detected, the
alarm bell will timeout as specified in
✱
33.
✱
34 EXIT DELAY 9 | 9
00 - 99 = exit delay time in seconds
The system will wait the time entered before sounding an alarm if the
exit door is left opened after the system has been armed.
✱
35 ENTRY DELAY 1 6| 0
00 - 99 = entry delay time in secs.
The system will wait the time entered before sounding alarm upon
entering.
UL installations: must be set for a maximum of 20 seconds
✱
36 ENTRY DELAY 2 9| 0
00 - 99 = entry delay time in secs.
The system will wait the time entered before sounding alarm upon
entering.
UL installations: must be set for a maximum of 20 seconds
✱
37 AUDIBLE EXIT WARNING 1
0 = no exit warning sound
1 = provide exit warning sound when armed AWAY
Warning sound consists of slow continuous beeps until last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of Exit time.
✱
38 CONFIRMATION OF ARMING DING 0
0 = no ding
1 = confirmation ding after arming system
2 = confirmation ding after arming from RF button or RF keypad only
(ding occurs when the system receives the RF transmission.)
Confirmation of arming is 1/2 second external sounder “ding” when
closing report is sent, or at the end of exit delay.
✱
39 POWER UP IN PREVIOUS STATE 1
0 = always power up in a disarmed state
1 = assume the system status prior to power down
When the system powers up armed, an alarm will occur 1 minute after
arming if a zone is faulted.
Note that if the previous state was armed AWAY or HOME, the
system will not respond to sensor changes for 1 minute, which allows
time for sensors such as PIRs to stabilize. This means that if a zone
faults during that 1 minute time period, the system will not detect the
faulting and would power up into the armed ON AWAY or ON HOME
original state.
UL installations: must be 1 (power up in previous state)