16–
SUPPLEMENTARY
POWER SUPPLY
+
CONTROL
TERMINAL STRIP
AUX AUX. DATA DATA
+ IN OUT
4567
IMPORTANT:
MAKE THESE
CONNECTIONS
DIRECTLY TO
SCREW
TERMINALS AS
SHOWN.
TO KEYPAD RED WIRE
TO KEYPAD BLK WIRE
TO KEYPAD YEL WIRE
TO KEYPAD GRN WIRE
TO KEYPAD BLK WIRE
TO KEYPAD RED WIRE
TO KEYPAD GRN WIRE
TO KEYPAD YEL WIRE
Figure 7. Using A Supplementary Power Supply For Keypads
Preliminary Check-out Procedure
If you want to check that the system is working before connecting field wiring
from zones and devices, do the following:
1. Temporarily connect a 2000 ohm end-of-line resistor across each of the
basic hard-wire zones 1–8, as shown in the Summary of Connections
diagram.
Without actual zone wiring or EOL resistors connected, the keypads of the
system will not display the “Ready” message.
2. Power up the system temporarily by plugging the AC transformer
(previously wired to the control) into a 120VAC outlet.
3. B u s y S t a n d b y (Alpha keypads) or dI (Fixed-word keypads) will be
displayed.
After approximately 1 minute*, the green “READY” LED (or “POWER”
LED on some types of keypads) should light, and the words READY
ENTER CODE (Fixed-word keypads), or **SYSTEM READY** (Alpha
keypads) should be displayed.
* To bypass the 1-minute delay, press [#] plus 0.
If the READY ENTER CODE display does not appear on any of the keypads
in the system, or a “Not Ready” message is displayed, check the keypad
wiring connections, and make sure each of the 8 basic hard-wired zones
has a 2000 ohm resistor connected across its terminals.
4. When you get the proper READY ENTER CODE displays on the keypad(s),
the system is functioning properly at this point.
Do not remove the EOL resistors until you are ready to make connections
to the hard-wired zones, to allow for testing later in the manual.
If an OC or OPEN CIRCUIT is present on the keypad, data from the control is
not reaching the keypad. Please check the wiring.