–41–
Programming For The Remote Keyswitch
1. With one 2-line Alpha keypad (AM6139), enter the programming mode by
entering:
Installer code + 8 + 0 + 0 keys.
If RF zones, wired expansion, or a keyswitch will be used, data fields
✱
22 RF
SYSTEM,
✱
25 WIRED ZONE EXPANSION and
✱
30 KEYSWITCH ENABLE
must be programmed as required prior to continuing.
Note: If keyswitch is enabled, in menu mode
✱
56 the Zone Type (ZT) for
zone 7 will show “77”, and will not be accessible for programming.
2. Press
✱
56.
Note that this is an interactive programming mode. You will use it to
program zone 7 for alarm report codes and to program response time
(zone type will automatically show as “77”).
E n t e r Zn Nu m .
( 0 0 = Q u i t ) 0 1
Zone Number ↑
Upon entering
✱
56 mode, this prompt will
be displayed.
Enter zone number “07”.
Following this entry, press
✱
to continue.
Typical summary display
Zn ZT RC In RT
07 77 00 HW: 1
A summary display will appear, showing the
present status of zone 7's programming.
Zn = zone number;
ZT = zone type;
RC = report code for that zone;
In = input type of zone;
RT = response time for that zone.
Values displayed are the factory defaults for
zone 7 or, if this is not a new installation,
they are the currently programmed values.
↓
Zone Number
0 7 Z o n e T y p e
7 7
Zone Type ↑
To program zone 07, press [
✱
].
Zone type will be automatically displayed as
“77”, and no entry is required.
Press [
✱
] to continue.
0 7 Re p o r t Co d e
1 s t 0 3 2 n d 1 2 3 C
The report code consists of 2 hexadecimal
digits, each in turn consisting of 2 numerical
digits. For example, for a report code of
"3C", enter [0][3] for "3" and [1][2] for "C".
If necessary, refer to Section 23. SYSTEM
COMMUNICATION for complete informa-
tion on report codes.
Enter the desired numbers and then press
[
✱
] to continue.