Datacom Systems D56 Specifikace Strana 8

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 108
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 7
Si5040
8 Rev. 1.3
Table 3. AC Characteristics–RXDIN (Receiver Input)
(V
DD
= 1.8 V +5/–10%, T
A
= –40 to 95 C)
Parameter Symbol Test Condition Min Typ Max Unit
RX Path Data Rate 9.80 9.95 11.35 Gbps
Input Return Loss (RXDIN) < 2 GHz
5GHz
10 GHz
15
10
5
dB
dB
dB
ALOS Range Analog Mode 10 400 mV
PPD
ALOS Step Size Analog Mode 1 mV
PPD
ALOS Relative Accuracy Analog Mode 1 mV
DLOS Range Consecutive Digits Mode 0.5 100 µs
DLOS Accuracy Consecutive Digits Mode 0.5 µs
ALOS Hysteresis
(Programmable 0.4 dB steps)
Analog Mode 0 6 dB
Slice Voltage Range mode = absolute or proportional –240 240 mV
D
Slice Voltage Error Max error from the programmed
absolute slice voltage
±20 %
Sample Phase Range –12 12 ps
Jitter Tolerance
OC-192
BER = 10
–12
J
TOL(PP)
f = 2.0 kHz 15 30 UI
PP
f = 20 kHz 1.5 3.0 UI
PP
f = 400 kHz 1.5 3.0 UI
PP
f=4MHz 0.4 UI
PP
f=80MHz 0.4 UI
PP
Acquisition Time (Default mode)
REFCLK
Referenceless
T
AQ
Register 86, bit 6:3 = 8 decimal
Register 68, bit 3:0 = 2 decimal
Register 67, bit 6:2 = 17 decimal
50
50
ms
ms
Frequency Difference at which
Receive PLL Goes Out of Lock
LOL 800 ppm
Frequency Difference at which
Receive PLL Goes into Lock
LOCK 200 ppm
Zobrazit stránku 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 107 108

Komentáře k této Příručce

Žádné komentáře